data center ups
"
Aire acondicionado de precisión de sala de servidores 8KW 13KW 17KW 20KW para equipos de centro de datos de laboratorio
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCNA1008F3Z3ACNA1013F3Z3ACNA1008F1Z3ACNA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration
8KW 13KW 17KW 20KW Aire acondicionado industrial para el sistema de refrigeración del centro de datos Peso 150 KG
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCNA1008F3Z3ACNA1013F3Z3ACNA1008F1Z3ACNA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration
Refrigeración CMA 25KW 30KW 35KW 40KW 45KW 50KW Aire acondicionado de sala de servidores para centro de datos
Product Description Specification Room-level precision air conditioning technical parameters and configuration table (single system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA1025UCMA1030UCMA1035UCMA1040UOutdoor unit modelCMT025SPCMT040SPCMT045SPCMT050SPEnergy efficiency ratio3.013.093.053.01Power Specifications380VAC/50HZMaximum current26A35A39A42ARecommended input space40A/4P50A/4P63A/4P63A/4PCooling capacity (kW)20.230.535.440.2Sensible
CMA 25KW 30KW 35KW 40KW 45KW 50KW Aire acondicionado de sala de servidores para laboratorio y centro de datos
Product Description Specification Room-level precision air conditioning technical parameters and configuration table (single system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA1025UCMA1030UCMA1035UCMA1040UOutdoor unit modelCMT025SPCMT040SPCMT045SPCMT050SPEnergy efficiency ratio3.013.093.053.01Power Specifications380VAC/50HZMaximum current26A35A39A42ARecommended input space40A/4P50A/4P63A/4P63A/4PCooling capacity (kW)20.230.535.440.2Sensible
Nivel de seguridad alto Visench CRA 12.5KW 25KW 40KW 50KW 60KW Aire acondicionado de precisión industrial para centro de datos
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
5000m3/h Visench CRA 12.5KW Aire acondicionado de precisión de sala de servidores para centro de datos de laboratorio
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
Visench CRA 12.5KW 25KW 40KW 50KW 60KW Aire acondicionado de precisión con enfriamiento por aire basado en habitaciones para centro de datos de laboratorio
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
Aire acondicionado de precisión refrigerado por aire con doble sistema de 100 kW para centro de datos de laboratorio
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
Visench Winner Pro 1KR Rack UPS OEM 1KVA 1KW 1000W 1 fase UPS en línea para el centro de datos
Product nameWinner Pro RackRated Capacity1KVA -10KVAPower Factor0.99Input Voltage208/220/230/240VACFrequency40Hz-70HzOutput Voltage208/220/230/240VACWaveformPure Sine waveBattery Type12V/9AHPHASESingle phase with grounHarmonic Distortion≤ 3 % THD (Linear Load),Harmonic DistortionCurrent Crest Ratio3:01Voltage Regulatior土1%Frequency Range47~ 53 Hz or 57~ 63 HzInverter to Bypass4 ms (Typical)Typical Recharge Time4 hours recover to 90% capacitySize(mm)310x438x88/410x438x88